An un-intentional roof fall occurred along No. 5 belt near survey station 3650. The fall was app. 50 feet long,20 feet wide, and 5 feet thick. The area was bolted with 4 foot resin bolts. The fall will not be cleaned up, the section will be relocated outby this area.