On weekly examination-there was a roof fall found int he #7 intake entery at break #19 10' inby spad #462 in a timbered off area, the fall was approx 7-8' high and about 40' long, it does not have ventilation on intake travelway blocked it may a may not be celaned up, fall was found at about 730 am