An unintentional roof fall occured on the Unit 3 working section in the last open crosscut of the No. 5 entry at the 8060 foot mark. The fall occured due to the fact of roof failure at and just above the anchor point. The fall measured 20' by 17' by 5'. The brows will be reinforced with longer roof bolts, fall area cleaned up, and fall area supported.