A roof fall occurred in the 2 Main North, #7 entry, intersection of crosscut #2. The fall measured approximately 30'X 19'X 6'. The area was bolted with 6' tension rebar bolts. The area was mined in November of 2000. An undetected slip was determined to be the cause of the fall.