# HOISTING
> MSHA accident `220052710010` · 09/26/2005 · Independent Salt Company
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** M D  Keener
- **Operator:** Independent Salt Company
- **Mine:** [1400411](https://api.ai-analytics.org/mine/1400411)
## Narrative

500KW generator portion of MG set was showing temperature readings in excess of nominal.  Investigation revealed some broken springs used to apply proper brush friction.  All brushes and some springs with holders were replaced.  Topeka office was notified of hoist shutdown and re-start.

---