# FALL OF ROOF OR BACK
> MSHA accident `220052840043` · 10/10/2005 · Long Branch Energy
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Long Branch Energy Corporation
- **Operator:** Long Branch Energy
- **Mine:** [4609073](https://api.ai-analytics.org/mine/4609073)
## Narrative

A fall occured 300 feet outby the face, 60 feet outby spad No. 249 in No. 6 entry at a 4-way intersection. The roof has multiple cracks and prior to the fall, timbers and heitzmann jacks had been installed. The fall was 60 ft. long, 20 ft. wide and 6-8 ft. thick.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*