A roof fall occured in the 1 South, #7 entry, between the pillar line of crosscut #48 and #49. The fall measured approximately 25'X18'X6'. The area was bolted with 6' tension rebar bolts. The area was mined in April of 2004. An undetected slip was determined to be the cause of the fall.