# FALL OF ROOF OR BACK
> MSHA accident `220052940055` · 10/19/2005 ·  Clean Energy Mining Co.
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Massey Energy Company
- **Operator:**  Clean Energy Mining Co.
- **Mine:** [1510753](https://api.ai-analytics.org/mine/1510753)
## Narrative

10-19-2005 ON THE #1 SECTION IN THE #5 NEUTRAL ENTRY A ROOF FALL MEASURING 60' X 19' X 5' HIGH OCCURRED AT 10:45 PM. THE ROOF SUPPORT WAS 5' TORQUE TENSION BOLTS & 8' ROPE BOLTS. THE AREA WILL BE CLEANED AND ADDITIONAL SUPPORT ADDED.

---