A roof fall was found at 10 am on 10/30/05. Fall was between entry 2 and 3 at survey station 8+90 7lms unit. Area had been mined sept 12, 2005 and was supported with 6' full resin pins. No inury or property damage resulted. Atea around fall was propped off. There are no plans to clean up this fall. Fall was approx. 9' high x 20' wide x 80' long.