An unintentional roof fall was found in the Northeast Mains, #1 Entry, 20 ft inby spad station #3181. The fall measured 50'L x 18'W x 5'H. This area was developed 7-23-04 and was supported with 5' torque tension rods, roof mat & oversized bearing plates (8"" x 8"").