A roof fall occured in the 1 Main East, intersection of #5 entry at crosscut #60. The fall measured approximately 25'x18'x9'. The area was supported with 6' tension rebar bolts and supplemental support consisting of five (5) 9' mega bolts. An undetected slip was determined to be the cause of the fall.