# FALL OF ROOF OR BACK
> MSHA accident `220053570029` · 12/19/2005 · Triad Underground Mining, L.L.C.
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** James River Coal Company
- **Operator:** Triad Underground Mining, L.L.C.
- **Mine:** [1202316](https://api.ai-analytics.org/mine/1202316)
## Narrative

AN UNINTENTIONAL ROOF FALL OCCURRED IN THE 2ND MW INTAKE XC60 BETWEEN #6 & #7 ENTRY. APPROX. 38'LONG X 9'HIGH X 17'WIDE. THIS AREA HAD LAMINATED LIMESTONE & HAD BEEN BOLTED WITH 4' & 6' RESIN BOLTS. THIS AREA HAD BEEN CRIBBED & DANGERED OFF PRIOR TO THE FALL FOR BAD ROOF CONDITIONS.

---