A roof fall occurred in the 1 East Panel, crosscut #98 in the pillarline between #5 entry and #6 entry measuring 30ft. x 18ft. x 5ft. Five foot fully grouted roof bolts were used to support the area. An undetected slip and kidney bed was determined to be the cause of the accident.