A roof fall was discovered in the Main East entry crosscut 36, entry 2. The fall measures approximately 7 ft high, 18 ft wide and 18 ft long. The entry was initally supported with 5 foot fully grouted resin bolts. The fall did not impede passage of men, or impair ventilation.