Fall occur in a 4-way intersection in the No. 3 belt entry 100 ft inby spad No. 17, 1600 ft. from the face. Rock is 30 ft. long by 20 ft. wide by 6-8 feet. thick. This area had been bolted with No. 5, 48 in. fully grouted bolts in April, 2005. Some surface cracks are present.