A roof fall occurred in the 3rd west #2 entry, 3570' station. The fall was approximately 19' long, 18' wide and 8' tall. The area was bolted with 6' and 8' point anchor bolts. The fall did not affect ventilation, travel, damage equipment or cause any injury.