A roof fall occurred in the 13 North Panel #8 entry in the intersection of cross-cut #3 and continuing through the intersection of cross-cut #6 measuring approximately 220ft. x 19ft. x 5ft. The area was supported with 5ft. tension rebar bolts. An undetected slip was determined to be the cause.