# FALL OF ROOF OR BACK
> MSHA accident `220060190031` · 01/18/2006 · ICG-Illinois, LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** International Coal Group Inc (ICG)
- **Operator:** ICG-Illinois, LLC
- **Mine:** [1102664](https://api.ai-analytics.org/mine/1102664)
## Narrative

A series of roof falls occurred between rooms 1 and 5 at survey station 4+70 at return room neck in 6LMS unit. Area had been mined November 25, 2005. Equipment had all been moved out of this set of rooms and mining is currently being done eleven x-cuts inby this area. Work is being done to secure area with secondary support, then seals will be built across these room necks.

---