← MSHA accidents

HOISTING

220060230041 · 01/17/2006 · Sisecam Wyoming, LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
OCI Company, Ltd.; Anadarko Petroleum Corp
Operator
Sisecam Wyoming, LLC
Mine
4800154

Narrative

While performing weekly inspection of #2 ore shaft, the control relay K-15 failed closed which prevented a resistor from limiting the current to the main loop contactor close coil. The coil overheated and failed. This caused the main loop contactor to open and shut down the hoist. Repaired at 13:40.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown