Worker on top of eng. module on Hyd. shovel installing air cleaner assembly, switching safety harness lanyard from one eye to another. Crane swinging away from area, glove became entangled with hook as he was pushing hook of crane out of the way. Worker was suspended until glove tore. He fell to ground resulting in fracture of left wrist, and acute L2 compression fracture.