A ground fall occurred at teh 4150-5740 heading. The fall of ground was approximately 22 feet high and 15 feet wide and buried the front deck of a MacLean bolter. The bolter operator had completed installing 3 rows of 12 feet roof bolts in the secondary heading and was in the cab to back the machine out when the rock fall occurred. The operator was not injured in this incident.