On the #1 panel off #5 Belt, near Spad 1263 between #1 and #4 entry on 1-26-2006 a roof fall was discovered. The fall measured 130' long X 20' wide X 6' Height. Fall occured in an out area. Area is only traveled on a weekly basis. 4' resin bolts were being used. Area was cribbed and timbered off. Ventilation was not disturbed.