An un-intentional roof fall occurred in the number 3 entry, 1 break inby 4074. The fall started in an intersection and fell through the crosscut from no. 3 entry towards no. 4 entry for a distance of about 30 feet. 48 inch resin bolts were being used. Fall was 20' wide, 30' long, and 8' high in highest point. MSHA and the State were called when the fall was found about 1:00 P.M.