# HOISTING
> MSHA accident `220060410043` · 02/06/2006 · Lyons Salt Company
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Peter E  Powell
- **Operator:** Lyons Salt Company
- **Mine:** [1400413](https://api.ai-analytics.org/mine/1400413)
## Narrative

Normal Hoisting made when a fuse blew on the main hoist motor cooling fan. This shut the hoist down and set the brakes. The fuse controlling the blower fan is located in the dc 2000 thy ristr control panel and is set up to shut the motor down and set the brakes on hoist if this blower fan fuse blows. This is a 4 amp fuse.

---