A fall of clay rock occured in the west mains #1 entry. Fall was 20 ft long, 16 ft wide, 13 ft high. Area was bolted with 6 ft double lock bolts and was also spot bolted with 12 ft (2) piece double lock bolts. Fall was outby the working section. no disreption of ventilation, no injuries or entrapment.