A roof fall was found during the weekly air course examination at 19+00 between main entries #6 and #7 west. The fall was 30""long, 17.5'wide and 6.5'high. The cross-cut was initially supported with 6' fully grouted resin bolts. Water was determined as the cause. The cross-cut was timbered and dangered out.