# HOISTING
> MSHA accident `220060720055` · 03/10/2006 · Emerald Coal Resources LP
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Foundation Coal Corporation
- **Operator:** Emerald Coal Resources LP
- **Mine:** [3605466](https://api.ai-analytics.org/mine/3605466)
## Narrative

The #1 elevator was out of service for a period exceeding thirty (30) minutes due to malfunction of the COMP chain and damage to the Buffer switch. The COMP chain was adjusted and the Buffer switch was replaced and the elevator placed back into operation. No escapeways were affected buy the outage.

---