Roof fall in #2 entry 18' Long, 5' Wide, 42"" thick. No injuries were reported. Roof fall occured 640' Outby section, reported to Lincoln Selfe on 4/7/2006 at 5:20 PM. Fall will not be cleaned up. All approaches have been timbered off. Ventilation and passage of people not affected. Area was supported with 42"" fully grouted bolts with 16' J-channel.