An un-intentional roof fall occurred in the LOB intersection of #2 entry to #1 entry near survey station 4355. The fall will not be cleaned up at this time. Fall dimensions are 19' wide x 50' long x 6' to 8' thick. 4' and 6' resin bolts were being used at the time of the fall. Fall was reported to the Pineville field office.