# FALL OF ROOF OR BACK
> MSHA accident `220061210083` · 04/24/2006 · Freeman United Coal Mining Company
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** General Dynamics Corp
- **Operator:** Freeman United Coal Mining Company
- **Mine:** [1102236](https://api.ai-analytics.org/mine/1102236)
## Narrative

Unintentional roof fall 3rd south submain 1580' mark #4 entry 3SSM. 18' long, 35' wide and 10' high. Bolted with 6' tension rebar bolts and 8' tension rebar bolts. Mined approx. 3/21/06.

---