← MSHA accidents

IGNITION OR EXPLOSION OF GAS OR DUST

220061370026 · 05/05/2006 · Exeter Coal Corporation

Details

Degree of injury
ACCIDENT ONLY
Classification
IGNITION OR EXPLOSION OF GAS OR DUST
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Cumberland Resources Corporation
Operator
Exeter Coal Corporation
Mine
4407106

Narrative

A possible methane ignition occurred on the 1-left off North Mains (mmu 002-0) section. The second cut inby the last open crosscut, no. 6 heading was being mined. After a shuttle car, the mining machine was being backed out of the face to set over. The cutter bits struck the mine floor & a possible frictional methane ignition occurred.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown