# IGNITION OR EXPLOSION OF GAS OR DUST
> MSHA accident `220061370027` · 05/01/2006 · Exeter Coal Corporation
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** IGNITION OR EXPLOSION OF GAS OR DUST
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Cumberland Resources Corporation
- **Operator:** Exeter Coal Corporation
- **Mine:** [4407106](https://api.ai-analytics.org/mine/4407106)
## Narrative

A possible methane ignition occurred on the 1-left off North Mains section (mmu 002-0). The second cut inby the last open crosscut (No.6 heading) was being mined. The miner operator was cutting down on the face & when the cutter bits struck the sandstone bottom, a possible frictional ignition occurred.

---