A roof fall occurred on the 3rd Main North Belt between 33 & 34 xcuts (03 Entry 103+90'). Fall was 18'W, 10'L, 6'H. Area was mined in Nov, 1993. Fall occurred due to deterioration of roof around existing roof bolts. Area was supported with 8' long point anchor roof bolts using 2' of glue & an anchor shell. Fall blocked the passage of material on the belt.