A roof fall measuring 19' wide x 120' long x 5' thick was found in the neutral entry 7800' from the working section at spad 38368. The fall occurred due to intermixed coal streaks and rock above 4' resin roof bolts. No injuries occurred as a result of the fall, ventilation was not affected nor the passage of men. Area was developed March 2001, fall was dangered off.