← MSHA accidents

FALL OF ROOF OR BACK

220061520050 · 05/30/2006 · ICG-Illinois, LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
International Coal Group Inc (ICG)
Operator
ICG-Illinois, LLC
Mine
1102664

Narrative

A roof fall was found at 11:30 AM on 5/30/2006, located at survey station 11+20 entry 6 in 6LMS. Fall was outby working section and area had been mined Feb.2005. Fall measured 20x20x10 high and had been supported with 8' full resin pins. No injury resulted but an intake stopping was destroyed. There are no plans to clean up this fall.

Source

Authoritative
MSHA Open Government Data