A roof fall was found at 11:30 AM on 5/30/2006, located at survey station 11+20 entry 6 in 6LMS. Fall was outby working section and area had been mined Feb.2005. Fall measured 20x20x10 high and had been supported with 8' full resin pins. No injury resulted but an intake stopping was destroyed. There are no plans to clean up this fall.