# FALL OF ROOF OR BACK
> MSHA accident `220061930048` · 07/03/2006 ·  Clean Energy Mining Co.
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Massey Energy Company
- **Operator:**  Clean Energy Mining Co.
- **Mine:** [1510753](https://api.ai-analytics.org/mine/1510753)
## Narrative

#8 Belt break 16. a fall occurred 30' L x 20' W x 6' H, no injuries, no equipment involved, and no restriction to the ventilation. The area will be rehabilitated by additional support. The roof strata is shale with no rider seam. Incident was investigated by Massey, OMSL and MSHA.

---