A roof fall measuring 30'long, 19'wide, 6'thick was discovered in the #1 return entry of out bound mains 20' inby spad 56261. Fall occurred due to laminated shale and rock streaks above the 5' fully resin roof bolts. Ventilation and the passage of men were not affected. No injuries or equipment was affected by a result of a fall.