An unintentional roof fall occurred at 24 break along the #4 underground belt conveyor in the #5 entry, size 60' Long X 7' high X 20' wide was supported with 4' fully grouted bolts with 10' cable bolts installed at intersections. No injuries, no equipment caught & ventilation was not interrupted. Fall will not be cleaned up. Roof fall was found during weekly examination.