An unintentional roof fall occurred in the intersection of the South West Mains in the # 7 entry, # 25 xc, 15+85. The cause of the roof fall was laminated and unconsolidated shale above the anchorage point. The area had 6' fully grouted rebar roof bolts for roof support.