On 8/2/06, unintentional roof fall occurred at the #46 crosscut in #1 entry this was located in the 3rd south, main west return. The area was initially supported with 10' point anchor roof bolts, the fall measured 35' x 20' x 10' high and the roof fall will not be cleaned up.