← MSHA accidents

FALL OF ROOF OR BACK

220062190065 · 08/01/2006 · Mettiki Coal WV, LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Alliance Resource Partners LP
Operator
Mettiki Coal WV, LLC
Mine
4609028

Narrative

A fall of roof 6 ft high, 16 ft wide by 20 ft long occurred on West Mains at the #10 Crosscut between #2 and #3 entry. The area had been supported. Strata was laminated with clay seams. Additional support will be set through the affected area. No equipment or property damage. Fall was called in and reported.

Source

Authoritative
MSHA Open Government Data