HOISTING
220062200007
· 08/02/2006 · Morton Salt Div/Morton International Inc
Details
Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years
Operator
Controller (parent)
Rohm & Haas Company
Operator
Morton Salt Div/Morton International Inc
Mine
3301993
Narrative
A worn air pressure regulator that controls the brake release mechanism, caused the hoist to stop below the collar. The regulator was replaced and air pressure re-adjusted to put the hoist back in service.