# FALL OF ROOF OR BACK
> MSHA accident `220062230058` · 08/03/2006 · Dana Mining Company Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** James L  Laurita Jr; Thomas A  Laurita
- **Operator:** Dana Mining Company Inc
- **Mine:** [4604387](https://api.ai-analytics.org/mine/4604387)
## Narrative

On 2-South #4 hdg - 7 bl fall approx 6'-7' high x 17' w x 40'-60' in length. Cover approx 250' area bolted with 5' resin bolts. The hdg was mined between a full, partial pillared block & solid block of Pittsburgh coal causing roof condition problems in seam. Affected area has been rebolted with 10' & 12' cable bolts & 6' 3/4"" resin bolts & boards. Hdg width narrowed down also.

---