An unintentional roof fall occurred at 48 break along the #5 underground belt conveyor in the #7 entry, size 18'Lx4'Hx20'W. Was supported with 4' fully grouted bolts. No injuries resulted from this fall. Roof fall will be cleaned up. Roof fall was found during the weekly examination.