# IGNITION OR EXPLOSION OF GAS OR DUST
> MSHA accident `220062490034` · 09/03/2006 · Canyon Fuel Company LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** IGNITION OR EXPLOSION OF GAS OR DUST
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Arch Resources Inc
- **Operator:** Canyon Fuel Company LLC
- **Mine:** [4201890](https://api.ai-analytics.org/mine/4201890)
## Narrative

At approximately 8:50 AM a frictional methane ignition occurred on the Gil-5 Longwall, at shield No. 15.  The flame was described as a small orange glow at the bottom of the cutter drum.  The flame lasted one to two seconds before it was extinguished by the cutter drum water sprays.

---