A roof fall measuring 60' long 18' wide 6' thick was discovered in the return entry spad 21542. Fall was 11,800' from the active section in an area developed 02/97 with 5' resin bolts. Neither ventilation nor the passage of men was affected, no injuries or equipment damage occurred from the fall. The perimeter of the fall was re supported with timbers and barricaded.