Production skip overtravel. While waiting for the release from high surge bin on surface to resume the hoisting cycle, the loaded west skip began to roll back and came to rest when the east skip encountered the crash beam below the hoist drum. Damage was confined to bent handrail on the east skip and 5 broken wooden dividing timbers below the west skip.