A roof fall occurred one crosscut outby #5 seal of the 2nd main north seals. The fall was approximately 22' wide, 22' long and 8' tall. The area was bolted with 8' point anchor bolts. The fall didn't affect ventilation, travel, cause injury or damage equipment.