An unintentional roof fall was discovered in the return air course about 3,000' outby the MMU 001 section. There were 2 return entries in this area. Cribs were built inby & outby the fall. The fall measured 18'-19' wide x 20'-25' long x 2'-6' thick. This area was bolted with 6' tension rebar bolts.