NO.5 entry; spad no. 2 brk. inby 9402; secondary airway track entry, two other entries open, Area secured, being developed for clean up. Size of fall: L-25ft, W-20ft.H-6ft. Type of roof support: resin; Several cribs and timbers installed prior to fall; No coal rider seam present; All entrances are breakered off; Area will be rehabilitated